GD-2134E Cable Identifier (Model GD-2134E)
GD-2134E Cable Identifier is a path detection instrument with strong comprehensive performance. It has multiple functions such as pipeline path detection, cable identification, pipeline grounding fault detection etc. The instrument consists of a transmitter, a transmitting current clamp, a receiver, a receiving flexible current clamp, a connecting test line, a stethoscope, an A-frame (optional), and RTK (optional).
-
DRM-10 DC Winding Resistance Meter
DRM-10 DC winding resistance tester is a precision instrument that efficiently diagnoses potential problems such as coil material defects, poor welding, loose connections, and broken strands by measuring winding resistance values. It utilizes a high-precision constant current source and four-wire measurement technology to automatically eliminate lead errors, providing stable readings within 3 seconds. With a sensitivity of 0.1 μΩ, it can accurately detect subtle resistance changes, ensuring stable and reliable measurement results.
-
GDSD-140 Dielectric Strength Test Set For Insulation Sample
GDSD-140 test device is mainly suitable for making breakdown strength and withstand voltage test of solid insulating materials (such as: plastic, rubber, laminated materials, films, resins, mica, ceramics, glass, insulating paint and other insulating materials and insulating parts) under power frequency voltage or DC voltage.
The electronic control system of the device is controlled by PLC, and the data collection method is photoelectrically isolated, which effectively solves the anti-interference problem in the test process. The man-machine operation is convenient, and the dynamic curve can be displayed in real time.
-
MRT-10 Insulation Resistance Tester
MRT-10 High Voltage Insulation Resistance Tester is a professional instrument developed and produced by HV HIPOT in accordance with IEC 61010-1 and other relevant standards. It is used to measure the insulation resistance of power transformers, cables, motors, lines and materials. It uses high-voltage DC injection technology to output a stable DC voltage to the device under test through an internal precision high-voltage generator, accurately measuring the leakage current and automatically calculating the insulation resistance value.
-
OVT-80T Insulation Oil Tester
The OVT-80T Insulating Oil Tester, developed and manufactured by HV HIPOT in accordance with relevant standards such as IEC 60156, ASTM D877, and ASTM D1816, is a professional instrument for testing the dielectric strength of insulating oils and evaluating their quality and performance. A single-chip microcomputer controls the internal boost system, applying an electric field and detecting the breakdown voltage of the insulating oil, providing a reliable basis for evaluating insulating oil quality.
-
DRM-20S DC Winding Resistance Tester
The DRM-20S three-phase DC winding resistance meter is a precision device that measures winding resistance to efficiently diagnose potential problems such as coil material defects, poor welding, loose connections, and broken wires. It integrates magnetic assist testing, three-phase testing (Yn, Y, and △ types), and demagnetization functions to fully meet the measurement needs of various winding structures.
-
GIT-450kVA/150kV PD-free AC Dielectric Test Set
The GIT-450kVA/150kV PD-free AC Dielectric Test Set is an advanced automatic withstand voltage tester designed in accordance with the latest national power industry standards. It utilizes PLC controller technology, 2.4G ISM networking, and an advanced human-machine interface. This test equipment is suitable for power frequency withstand voltage testing and partial discharge testing of high-voltage electrical equipment of 150kV and below.The max. capacitance of tested object is 0.05μF at 150kV.
-
RE-MCF Trolley-Type Cable Fault Comprehensive Test System
RoBot-Eye Series fully integrated cable fault testing system combines multiple functions, including low-voltage pulse distance measurement, high-voltage pulse current distance measurement, acoustic-magnetic induction pinpointing, audio reception pinpointing, and step-voltage pinpointing. It is primarily used for locating faults such as broken wires, short circuits, and ground leakage faults (with ground insulation resistance below 0.5 megohms) in high- and low-voltage buried power cables. It can also identify high-resistance ground faults, flashover ground faults, and detect the depth and path direction of buried cables.
-
OVT-80K Insulation Oil Tester
OVT-80K Insulating Oil Dielectric Strength Tester, developed and manufactured by HV HIPOT in accordance with relevant standards such as IEC 60156, ASTM D877, and ASTM D1816, is a professional instrument for testing the dielectric strength of insulating oils and evaluating their quality and performance.
-
HPCI SER. Primary Current Injection Test Set
HPCI SER. Primary Current Injection Test Set uses digital control technology, with strong anti-interference ability.It features a low-power, high-capacity auto-coupled voltage regulator and a current transformer built with a high-permeability iron core, resulting in high output power, compact size, and light weight. It is mainly used for primary busbar protection and various current transformer ratio tests, and is widely used in scientific research, production, and electrical testing at power, railway, petrochemical, metallurgical, and mining companies.
-
GDYT-10/100 Partial Discharge Testing System 10kVA/100kV
This set of equipment is mainly used for partial discharge measurement and other scientific experimental research.
-
TWR-S Transformer Turns Ratio Tester
TWR-S Transformer Turns Ratio Tester can be used for three-phase transformer testing in power systems, especially for Z-type winding transformers, rectifier transformers and Scott, reverse Scott, and balanced transformer testing in railway electrical systems. It is an ideal transformer ratio group polarity tester for power systems, transformer manufacturers and railway electrical systems.